Induction heating up to 5000 kVAr,5 kHz

Giá bán: Liên hệ

Induction heating up to 5000 kVAr,5 kHz

Induction heating up to 5000 kVAr,5 kHz

 

 

 

 

 

 

 

 

 

 

 

Maximální hodnoty
 Max. output [QNmax]  5 000 kvar
 Max.voltage [UNmax]  2 000 V
 Max. current [INmax]  4 000 A
 Frequency range [fN]  5 000 Hz
Design
  • Dielectric – ALL film type
  • brass sheet welded casing, casing varnisch RAL 7035
  • dead case

 

Technical data
 Standars  IEC 60110-1; 1998     EN 60110-1;1998
 Capacitance tolerance  -5 / +10 %
 Ambient temperature  1 / 50 °C
 Maximal temperature of outlet water  +40 °C
 Power losses  < 0,3 W / kvar
 Flow rate  > 5 – 10 l / min
 Pressure drop at 5 l / min  > 0,6 bar
 Water pressure  6 bar
 Over-voltage  1,05 x UNmax max. 12 hours / 1  day
 Over-current  1,15 x IN
 Protection degree  IP00, indoor instalation
 Mounting position  vertical
 Voltage test between terminals  2 x UAC for 10 s or 4 x UN DC  for 10 s
 Voltage test between terminals and case
(for FRHJS 61xx)
 5 000 V AC for 10 s

 

Type FRHJS 6132

Type PDF Voltage
UN [V]
Capacitance
CN [µF]
Tapping
capacitance
[µF]
Frequency
fN [Hz]
Power
QN [kvar]
Current
IN [A]
FRHJS 6132-0,75/211/3,75  3BF1595 750 211 10×21,1 3 750 2 800 3 730
FRHJS 6132-0,75/265/2,5  3BF1595 750 265 10×26,5 2 500 2 350 3 133
FRHJS 6132-0,8/200/2,5  3BF1595 800 200 10×20 2 500 2 010 2 513
FRHJS 6132-1,0/159/3,75  3BF1595 1 000 159 10×15,9 3 750 3 750 3 750
FRHJS 6132-1,5/94/3,75  3BF1595 1 500 94 10×9,4 3 750 5 000 3 333

Type FRHJS 6140

Type PDF Voltage
UN [V]
Capacitance
CN [µF]
Tapping
capacitance
[µF]
Frequency
fN [Hz]
Power
QN [kvar]
Current
IN [A]
FRHJS 6140-0,8/320/2,5  3BF1595 800 320 10×32 2 500 3 217 4 021

Type FRHJS 6145

Type PDF Voltage
UN [V]
Capacitance
CN [µF]
Tapping
capacitance
[µF]
Frequency
fN [Hz]
Power
QN [kvar]
Current
IN [A]
FRHJS 6145-0,8/497/1,25  3BF1595 800 497 10×49,7 1 250 2 500 3 125
FRHJS 6145-1,0/398/1,25  3BF1595 1 000 398 10×39,8 1 250 3 125 3 125